Skip to main content

Advertisement

Advertisement

ADVERTISEMENT

Radiation Protection

Original Contribution
10/28/2016

Davide Maccagni, RT1,2;  Cosmo Godino, MD1;  Azeem Latib, MD1,3;  Morena Mancin, RT1;  Alaide Chieffo, MD1; Alberto Margonato, MD1;  Antonio Colombo, MD1,3

Davide Maccagni, RT1,2;  Cosmo Godino...
This study determines the patient radiation exposure and contrast agent variation during transcatheter aortic valve implantation procedures resulting from technological improvements.
This study determines the patient radiation exposure and contrast agent variation during transcatheter aortic valve implantation procedures resulting from technological improvements.
This study determines the...
10/28/2016
Journal of Invasive Cardiology
Commentary
10/28/2016

Prakash Balan, MD, JD and H. Vernon Anderson, MD

Prakash Balan, MD, JD and H. Vernon A...
The authors offer a commentary on this month's article by Maccagni et al, who describe their experience with contrast use and radiation exposure in transcatheter aortic valve replacement procedures over certain time intervals.
The authors offer a commentary on this month's article by Maccagni et al, who describe their experience with contrast use and radiation exposure in transcatheter aortic valve replacement procedures over certain time intervals.
The authors offer a commentary...
10/28/2016
Journal of Invasive Cardiology
Original Contribution
06/29/2015

Deborah Shorrock1,2;  Georgios Christopoulos, MD1;  Jedrek Wosik, MD1;  Anna Kotsia, MD1;  Bavana Rangan, BDS, MPH1;  Shuaib Abdullah, MD1;  Daisha Cipher, MD1;  Subhash Banerjee, MD1;  Emmanouil S. Brilakis, MD, PhD1  

Deborah Shorrock1,2;  Georgios Christ...
Daily radiation exposure in the cath lab over many years can adversely impact the health of medical professionals. This study recorded operator radiation exposure at a single institution and compared exposure of operators using the Radpad...
Daily radiation exposure in the cath lab over many years can adversely impact the health of medical professionals. This study recorded operator radiation exposure at a single institution and compared exposure of operators using the Radpad...
Daily radiation exposure in the...
06/29/2015
Journal of Invasive Cardiology
Cath Lab Management
01/06/2012

Jane Kiah, RN, Director of Invasive Services, Baptist Cardiac & Vascular Institute, Miami, Florida; Program Director, Innovations in Cardiac and Vascular Care: Advanced Interventions for Nurses and Technologists, The International Symposium on Endovascular Therapy (ISET)

Dick Stueve, RT, radiation safety consultant to Philips Healthcare, providing on-site radiation safety courses for physicians, nurses and technologists performing fluoroscopically guided vascular interventions.

Jane Kiah, RN, Director of Invasive S...
Marie Curie died due to excess exposure to her discovery, radium. Thomas Edison invented the fluoroscope, but stopped his work in this area when his assistant died of an x-ray overdose. Many years later, we have a better understanding of the...
Marie Curie died due to excess exposure to her discovery, radium. Thomas Edison invented the fluoroscope, but stopped his work in this area when his assistant died of an x-ray overdose. Many years later, we have a better understanding of the...
Marie Curie died due to excess...
01/06/2012
Cath Lab Digest
Clinical Editor's Corner
06/01/2011

Morton Kern, MD, Clinical Editor, Professor of Medicine, Associate Chief Cardiology University of California Irvine, Orange, California mortonkern2007@gmail.com

Morton Kern, MD, Clinical Editor, Pro...
I recently learned that I could see my real-time x-ray dose while doing a case. My x-ray system (Philips, Bothell, Wash.) has a display (see Figures) on the left side of the monitors that shows my table height, source-to-image distance (SID),...
I recently learned that I could see my real-time x-ray dose while doing a case. My x-ray system (Philips, Bothell, Wash.) has a display (see Figures) on the left side of the monitors that shows my table height, source-to-image distance (SID),...
I recently learned that I could...
06/01/2011
Cath Lab Digest

Advertisement

Advertisement

Advertisement