Skip to main content

Advertisement

ADVERTISEMENT

A Study of Left Renal Artery Pseudoaneurysm With Multiple Fractures of Stent

Ash Jain, MD; Lamiya Sheikh, MS

 

Washington Hospital Healthcare System, Fremont, California

May 2014

ABSTRACT: Percutaneous renal angioplasty with stenting is the predominant method of intervention for artherosclerotic renal artery stenosis. We present the relatively rare complication of formation of pseudoaneurysm after stent fracture in the case of a 74-year-old male with flash pulmonary edema and severe hypertension associated with renal artery stenosis and stenting, followed by formation of a large pseudoaneurysm in his left renal artery. We discuss management of such patients. We recommend that clinicians perform follow-up imaging on patients undergoing renal artery angioplasty for restenosis of renal artery stent to rule out the possibility of stent fracture and pseudoaneurysm formation.

VASCULAR DISEASE MANAGEMENT 2014;11(5):E108-E113

Key words: renal artery stenosis, pseudoaneurysm, stenting, complications, balloon angioplasty

___________________________

Renovascular disease affects approximately 2 million to 4 million people in the United States every year. Stenting has become the standard endovascular intervention for atherosclerotic lesions.1-8 The prevalence of renal artery stenosis (RAS) is high in patients with peripheral vascular disease, renal insufficiency, and coronary heart disease.9-14 The incidence among Medicare patients, as of 1999-2001 was reported as 3.7 per 1,000 patient years.15 The prevalence of RAS among certain at-risk populations varies from 3% to 75%.16-18

RAS is generally treated medically, or with a balloon angioplasty with stenting. Indications of stenting have been changing, especially in the recent past, due to poor long-term results. Complications associated with the stenting procedure are well documented in the literature. They vary from dissection, rupture, or separation of the artery19-22 to perforation of parenchyma23,24 to perinephric hematoma19,20,25 and groin complications.25

A recent literature review has shown that there are very few documented cases of complications resulting from stent fracture in renal arteries26-28 and even fewer documented cases of pseudoaneurysm following renal stent fracture,29-31 which may not be obviously detected unless they are specifically suspected and investigated.30 Reports have shown that the left renal artery may be more susceptible to stent fracture than the right renal artery.26

In this paper we describe a case of left renal artery stent fracture after balloon angioplasty and subsequent pseudoaneurysm formation. 

Case Presentation

A 74-year-old male was admitted with shortness of breath and flash pulmonary edema. He was severely hypertensive and had elevated brain natriuretic peptide (BNP) of 4,340. There was an underlying history of heart disease, bilateral renal artery stenosis, methicillin-resistant Staphylococcus aureus hip infection, and recurrent flash pulmonary edema. 

Treatment

The patient had been aggressively managed for hypertension and for ischemic heart disease. Bilateral renal artery stenosis intervention had been performed, with bilateral proximal renal artery stents (6 mm x 18 mm, Medtronic stents) placed approximately 1 year prior to presentation. The patient had an angioplasty (6 mm x 20 mm balloon catheter) of left renal artery 8 months later for restenosis within the stent (Figure 1).

During the current admission, the patient was diuresed, which resulted in some improvement of his symptoms and a dobutamine stress echocardiogram was performed, which showed posterior wall hypokinesis with stress. Ten days after admission, a diagnostic catheterization procedure was performed, which showed a lesion in the obtuse marginal vessel and pseudoaneurysm at the site of the left renal artery stent with multiple fractures of stent struts (Figure 2). An abdominal computed tomography angiography was performed to better define the pseudoaneurysm, which showed a circumferential pseudoaneurysm at the area of the stent without a neck and with thin walled encapsulation (Figures 3 and 4).

Of interest was that the patient had previous left common iliac aneurysms, which had been treated with covered stents. A tagged white blood cell (WBC) scan of this area was obtained to rule out mycotic aneurysm because the patient had previous iliopsoas abscess and infected left hip hardware. The WBC scan was negative. 

Results

The patient was treated medically, stabilized, and discharged. Five days post discharge, the patient was readmitted with shortness of breath and flash pulmonary edema, and was again treated medically. A covered stent was not placed because the patient became septic and subsequently expired, possibly due to sepsis complications and precluding any further treatment.

Clinically significant RAS diagnosis and treatment options have been a dilemma for clinicians. Indications for treatment with balloon angioplasty and stenting have been an issue of debate. It is unclear when and how to treat patients and results have been varying. The embolic protection device, although used for renal artery stenting, has been an important development and may benefit clinical outcomes, but studies so far have only included a small number of patients. Complications after RAS angioplasty and stenting include access site complications, as secondary to renal artery dilatation, embolization, wire perforations, and loss of renal function.

Here we discuss a case with renal artery stenosis causing severe uncontrolled hypertension and flash pulmonary edema. The patient showed an immediate abatement of symptoms after bilateral renal artery stenting. However this was followed by restenosis of the left renal artery stent and subsequent balloon angioplasty. Thereafter it was discovered that the patient had stent fractures with the development of a pseudoaneurysm. It was interesting to note that the pseudoaneurysm did not have a neck as ordinarily seen, but was all around the proximal artery and contained by a thin wall of tissue. This was likely due to the stent fracture causing a perforation leading to a leak contained by the surrounding tissue. The patient’s local symptoms had remained stable, but he had uncontrolled hypertension and multiple admissions for pulmonary edema.

The association between stent fractures and pseudoaneurysm in peripheral arteries other than the renal artery is well documented. However a review of current literature shows that there have been few reported cases of stent fractures in the renal artery in recent years and only 1 case associated with pseudoaneurysm.26-29,31 There is an apparent relationship between incidence of pseudoaneurysm and stent fractures. However, it is unclear whether spontaneous stent fractures result in a pseudoaneurysm or if the dilation of a restenotic stent with balloon angioplasty and the resultant stent fracture causes pseudoaneurysms. 

Management of pseudoaneurysm in renal arteries is through observation, surgery, or percutaneous exclusion of the pseudoaneurysm.20,23,32,33 Currently there are no guidelines detailing which of these options is best. We chose to observe the patient and prepare for excluding the pseudoaneurysm with a covered stent. However the approach and choice of self-expanding vs balloon expanding covered stents is debatable. 

Conclusion

As evidenced by the literature, stent fractures resulting in pseudoaneurysm in the renal artery are a rare occurrence or underdiagnosed. Based on our experience we recommend that patients with stent fractures in renal arteries undergo imaging to exclude pseudoaneurysm, as this can result in increased morbidity and mortality. 

Editor’s Note: Disclosure: The authors have completed and returned the ICMJE Form for Disclosure of Potential Conflicts of Interest. The authors report no disclosures related to the content of this manuscript. 

Manuscript submitted October 16, 2013; provisional acceptance given November 13, 2013; final version accepted November 26, 2013. 

Address for correspondence: Lamiya Sheikh,Washington Hospital Healthcare System, Department of Cardiology, 2500 Mowry Avenue, Fremont, CA 94538, United States. Email: lamiya_sheikh@whhs.com. 

References  

  1. Singh KP, Patel MR, Kandzari DE, Zidar JP. Peripheral arterial disease: an overview of endovascular therapies and contemporary treatment strategies. Rev Cardiovasc Med. 2006;7(2):55-68.
  2. Bush RL, Najibi S, MacDonald MJ, et al. Endovascular revascularization of renal artery stenosis: technical and clinical results. J Vasc Surg. 2001;33(5):1041-1049.
  3. van de Ven PJ, Kaatee R, Beutler JJ, et al. Arterial stenting and balloon angioplasty in ostial atherosclerotic renovascular disease: a randomized trial. Lancet. 1999;353(9149):282–286. 
  4. Henry M, Amor M, Henry I, et al. Stents in the treatment of renal artery stenosis: long-term follow-up. J Endovasc Surg. 1999;6(1):42-51. 
  5. Henry M, Amor M, Henry I et al. Stent placement in the renal artery: three-year experience with the Palmaz stent. J Vasc Interv Radiol. 1996;7(3):343-350. 
  6. Blum U, Krumme B, Flugel P, et al. Treatment of ostial renal artery stenosis with vascular endoprotheses after unsuccessful balloon angioplasty. N Engl J Med. 1997;336(7):459-465.
  7. van de Ven PJ, Beutler JJ, Kaatee R, et al. Transluminal vascular stent for ostial atherosclerotic renal artery stenosis. Lancet. 1995;346(8976):672-674. 
  8. Dorros G, Jaff M, Jain A, Dufek C, Mathiak L. Follow-up of primary Palmaz–Schatz stent placement for atherosclerotic renal artery stenosis. Am J Cardiol. 1995;75(15):1051-1055. 
  9. Rihal CS, Textor SC, Breen JF, et al. Incidental renal artery stenosis among a prospective cohort of hypertensive patients undergoing coronary angiography. Mayo Clin Proc. 2002;77(4):309-316.
  10. Missouris CG, Buckenham T, Cappuccio FP, MacGregor GA. Renal artery stenosis: a common and important problem in patients with peripheral vascular disease. Am J Med. 1994;96(1):10-14.
  11. Gross CM, Kramer J, Waigand J, et al. Ostial renal artery stent placement for atherosclerotic renal artery stenosis in patients with coronary artery disease. Cath Cardiovasc Diagn. 1998;45(1):1-8.
  12. Jean WJ, al-Bitar I, Zwicke DL, Port SC, Schmidt DH, Bajwa TK. High incidence of renal artery stenosis in patients with coronary artery disease. Cathet Cardiovasc Diagn. 1994;32(1):8-10. 
  13. O’Neil EA, Hansen KJ, Canzanello VJ, Pennell TC, Dean RH. Prevalence of ischemic nephropathy in patients with renal insufficiency. Am Surg. 1992;58(8):485-490. 
  14. Hansen KJ, Edwards MS, Craven TE, et al. Prevalence of renovascular disease in the elderly: a population based study. J Vasc Surg. 2002;36(3):443-451. 
  15. Kalra PA, Guo H, Kausz AT, et al. Atherosclerotic renovascular disease in United States patients aged 67 years or older: risk factors, revascularization, and prognosis. Kidney Int. 2005;68(1):293-301.
  16. Mistry S, Ives N, Harding J, et al. Angioplasty and STent for Renal Artery Lesions (ASTRAL trial): rationale, methods and results so far. J Hum Hypertens. 2007;21(7):511-515.
  17. de Mast Q, Beutler JJ. The prevalence of artherosclerotic renal artery stenosis in risk groups: A systematic literature review. J Hypertens. 2009;27(7):1333-1340.
  18. Kuczera P, Włoszczyńska E, Adamczak M, Pencak P, Chudek J, Wiecek A. Frequency of renal artery stenosis and variants of renal vascularization in hypertensive patient: analysis of 1550 angrographies in one center. J Hum Hypertens. 2009;23(6):396-401.
  19. Leertouwer TC, Gussenhoven EJ, Bosch JL, et al. Stent placement for renal arterial stenosis: where do we stand? a meta-analysis. Radiology. 2000;216(1):78-85.
  20. Bannazadeh M, Sarac T. Renal artery stenting: efficacy and complications. Curr Hypertens Rev. 2009;5(1):7-12.
  21. Geroulakos G, Missouris C, Mitchell A, Greenhalgh RM. Endovascular treatment of renal artery stenosis. J Endovasc Ther. 2001;8(2):177-185.
  22. Jebara VA, El Rassi I, Achouh PE, Chelala D, Tabet G, Karam B. Renal artery pseudoaneurysm after blunt abdominal trauma. J Vasc Surg. 1998; 27(2): 362-5. 
  23. Textor SC, Lerman L, McKusick M. The uncertain value of renal artery interventions: where are we now? JACC Cardiovasc Interv. 2009;2(3):175-182.
  24. Schillinger M, Minar E. Complications in Renal and Mesenteric Vascular Interventions. In: Complications in Peripheral Vascular Interventions, 1st edition. London: Informa Healthcare; 2007: pp. 159-176.
  25. Bax L, Woittiez AJ, Kouwenberg HJ, et al. Stent placement in patients with atherosclerotic renal artery stenosis and impaired renal function: a randomized trial. Ann Intern Med. 2009;150(12):840-848.
  26. Robertson SW, Jessup DB, Boero IJ, Cheng CP. Right renal artery in vivo stent fracture. J Vasc Interv Radiol. 2008;19(3):439-442.
  27. Baguet JP, Thony F, Sessa C, Mallion JM. Stenting of a renal artery compressed by the diaphragm. J Hum Hypertens. 2003;17(3):213-214.
  28. Bessias N, Sfyroeras G, Moulakakis KG, Karakasis F, Ferentinou E, Andrikopoulos V. Renal artery thrombosis caused by stent fracture in a single kidney patient. J Endovasc Ther. 2005;12(4):516-520.
  29. Schuurman JP, de Vries JP, Vos JA, Wille J. Renal artery pseudoaneurysm caused by a complete stent fracture: A case report. J Vasc Surg. 2009;49(1):214-216.
  30. McWilliams RG, Godfrey H, Bakran A, Kool LJ, van Bockel JH, van Oostayen JA. Delayed pseudoaneurysm after renal artery angioplasty. J Endovasc Ther. 2002;9(1):48-53.
  31. Sahin S, Memiş A, Parildar M, Oran I. Fracture of a renal artery stent due to mobile kidney. Cardiovasc Intervent Radiol. 2005;28(5):683–685.
  32. Patel RA, White CJ. Tips and tricks in renal artery angioplasty and stenting: angiography, stent placement, embolic protection, complications, and contrast induced nephropathy. Minerva Cardioangiol. 2010;58(1):113-126.
  33. Stavrinou E, Koumaras C, Gossios TD, Tziomalos K, Athyros VG, Karagiannis A. Atherosclerotic renal artery stenosis: an update on diagnosis and management. Curr Vasc Pharmacol. 2011;9(4):465-470.
  34. Deitch JS, Hansen KJ, Regan JD, Burkhart JM, Ligush J Jr. Infected renal artery pseudoaneurysm and mycotic aortic aneurysm after percutaneous transluminal renal artery angioplasty and stent placement in a patient with a solitary kidney. J Vasc Surg. 1998;28(2):340-344. 
  35. Simon JF. Stenting atherosclerotic renal arteries: time to be less aggressive. Cleve Clin J Med. 2010;77(3):178-189.

Advertisement

Advertisement

Advertisement