Skip to main content

ADVERTISEMENT

Takeshi Yamada, MD

07/23/2019
This is the first case report of pseudoaneurysm formation after cardiac catheterization through the distal radial artery, which was easily treated by external compression.
This is the first case report of pseudoaneurysm formation after cardiac catheterization through the distal radial artery, which was easily treated by external compression.
This is the first case report of...
07/23/2019
Journal of Invasive Cardiology
09/03/2018
The distal radial approach from the anatomical snuff box on the dorsal side of the hand was first described to open occluded ipsilateral radial arteries.1 This new vascular access site has recently been introduced for percutaneous coronary...
The distal radial approach from the anatomical snuff box on the dorsal side of the hand was first described to open occluded ipsilateral radial arteries.1 This new vascular access site has recently been introduced for percutaneous coronary...
The distal radial approach from...
09/03/2018
Cath Lab Digest
Original Contribution
04/01/2022
Distal radial artery access is a novel alternative to conventional radial artery access for coronary catheterization. This study investigated the incidence of vascular complications with percutaneous coronary intervention from DRA access...
Distal radial artery access is a novel alternative to conventional radial artery access for coronary catheterization. This study investigated the incidence of vascular complications with percutaneous coronary intervention from DRA access...
Distal radial artery access is a...
04/01/2022
Journal of Invasive Cardiology
02/04/2013
We describe a case in which fragment retrieval using the twin wire method11 was unsuccessful; this resulted in penetration of the aortic wall by the proximal side of the fractured wire fragment.
We describe a case in which fragment retrieval using the twin wire method11 was unsuccessful; this resulted in penetration of the aortic wall by the proximal side of the fractured wire fragment.
We describe a case in which...
02/04/2013
Cath Lab Digest
Original Contribution
01/27/2012
Abstract: Background. Crush stenting mandates a final kissing-balloon technique (KBT) for a better clinical outcome; however, recrossing the 2 overlapping stent struts with the balloon catheter is technically challenging. Objectives. The...
Abstract: Background. Crush stenting mandates a final kissing-balloon technique (KBT) for a better clinical outcome; however, recrossing the 2 overlapping stent struts with the balloon catheter is technically challenging. Objectives. The...
Abstract: Background. Crush...
01/27/2012
Journal of Invasive Cardiology