Skip to main content

ADVERTISEMENT

Norio Tada, MD

05/29/2012
Abstract: Percutaneous transcatheter aortic valvuloplasty is seriously limited by high restenosis rates. We report a case where the use of a buddy-catheter technique during balloon inflation allowed increased focused force onto calcified...
Abstract: Percutaneous transcatheter aortic valvuloplasty is seriously limited by high restenosis rates. We report a case where the use of a buddy-catheter technique during balloon inflation allowed increased focused force onto calcified...
Abstract: Percutaneous...
05/29/2012
Journal of Invasive Cardiology
Original Contribution
11/01/2015
We aimed to investigate the feasibility and safety of alcohol septal ablation (ASA) via transradial approach using a sheathless guiding catheter. 
We aimed to investigate the feasibility and safety of alcohol septal ablation (ASA) via transradial approach using a sheathless guiding catheter. 
We aimed to investigate the...
11/01/2015
Journal of Invasive Cardiology
Radial Access Technique
04/29/2015
We conducted a retrospective investigation of all TRIs performed at Sendai Kousei Hospital from January 2004 to December 2013 to evaluate the efficacy and safety of sheathless TRI in a large population (n=9658).
We conducted a retrospective investigation of all TRIs performed at Sendai Kousei Hospital from January 2004 to December 2013 to evaluate the efficacy and safety of sheathless TRI in a large population (n=9658).
We conducted a retrospective...
04/29/2015
Journal of Invasive Cardiology
Original Contribution
08/28/2018
We investigated whether a newly designed strategy of immediate transradial intervention using one sheathless hydrophilic-coated guiding catheter after diagnostic coronary angiography with one 4.0 Fr sheath via a single access site (the...
We investigated whether a newly designed strategy of immediate transradial intervention using one sheathless hydrophilic-coated guiding catheter after diagnostic coronary angiography with one 4.0 Fr sheath via a single access site (the...
We investigated whether a newly...
08/28/2018
Journal of Invasive Cardiology
Original Contribution
06/24/2022
The Hyperion SheathLess guiding catheter (Asahi Intecc) is a novel guiding system for transradial percutaneous coronary intervention (PCI). Compared with the previous model (SheathLess Eaucath; Asahi Intecc), improvements achieved with the...
The Hyperion SheathLess guiding catheter (Asahi Intecc) is a novel guiding system for transradial percutaneous coronary intervention (PCI). Compared with the previous model (SheathLess Eaucath; Asahi Intecc), improvements achieved with the...
The Hyperion SheathLess guiding...
06/24/2022
Journal of Invasive Cardiology