Palpation-guided access of the radial artery (RA) has transradial access (TRA) failure rates averaging 6%-7%. This study aimed to measure RA and ulnar artery (UA) diameters by ultrasound in a typical American population, in hopes of...
Palpation-guided access of the radial artery (RA) has transradial access (TRA) failure rates averaging 6%-7%. This study aimed to measure RA and ulnar artery (UA) diameters by ultrasound in a typical American population, in hopes of...
Nathan Kong, MD1; Kiersten Rasberry2; Daniel Gold, MD1; Matthew Gold, MD1; Linda Lee, MD2; Joseph Kern, MD2; Frank Medina, BS2; Kiran Kaur, BS2; Janet Friant, APN2; Jonathan Paul, MD2; Rohan Kalathiya, MD2; Atman P. Shah, MD2; Sandeep Nathan, MD2; John Blair, MD2
Nathan Kong, MD1; Kiersten Rasberry2...
The transulnar approach has been proposed as a safe alternative to the more established transradial approach for cardiac catheterization. However, no study has assessed the anatomy and variability of the ulnar artery using angiography.
The transulnar approach has been proposed as a safe alternative to the more established transradial approach for cardiac catheterization. However, no study has assessed the anatomy and variability of the ulnar artery using angiography.
Cardiovascular Institute of the South, Houma, Louisiana
Craig Walker, MD, FACC, FACP
Card...
Craig Walker, MD, discusses Ansaarie et al’s article, “A Retrospective Cohort Study to Evaluate the Efficacy and Safety of Minimal Arterial Access Lower-Extremity Intervention Via Peripheral Orbital Atherectomy.”
Craig Walker, MD, discusses Ansaarie et al’s article, “A Retrospective Cohort Study to Evaluate the Efficacy and Safety of Minimal Arterial Access Lower-Extremity Intervention Via Peripheral Orbital Atherectomy.”
We report a pseudoaneurysm (PSA) in a patient who underwent coronary angiography via left distal transradial access (ldTRA) 3 months previously. This is the reported case of pseudoaneurysm formation following ldTRA.
We report a pseudoaneurysm (PSA) in a patient who underwent coronary angiography via left distal transradial access (ldTRA) 3 months previously. This is the reported case of pseudoaneurysm formation following ldTRA.
Keith Andrew L. Chan, MD, Francisco L. Chio Jr, MD, FACC, FACP, FSCAI, Chong Hua Heart Institute, Chong Hua Hospital, Cebu City, Philippines
Keith Andrew L. Chan, MD, Francisco L...
We believe this case is one of the first documented cases of a successful SVG intervention via the left distal radial snuffbox approach, as well as the first of its kind to be documented in the Southeast Asian region.
We believe this case is one of the first documented cases of a successful SVG intervention via the left distal radial snuffbox approach, as well as the first of its kind to be documented in the Southeast Asian region.
The main objective of this study was to assess the safety and feasibility of orbital atherectomy with transradial access compared with more traditional femoral access.
The main objective of this study was to assess the safety and feasibility of orbital atherectomy with transradial access compared with more traditional femoral access.
Ferdinand Kiemeneij1, MD, PhD, Darren Klass2, MD, PhD, and Sandeep Nathan3, MD, MSc
Ferdinand Kiemeneij1, MD, PhD, Darren...
Accessing the radial artery distal to the wrist in the anatomic snuffbox is a reasonable option for primary access, as well as a suitable bailout option.
Accessing the radial artery distal to the wrist in the anatomic snuffbox is a reasonable option for primary access, as well as a suitable bailout option.
Sheharyar Minhas, MD1, Kevin Barretto2, Maira Malik2,3, Sunil Dhar, MD1,2
1Department of Cardiology; Department of Internal Medicine, Nazareth Hospital, Philadelphia, Pennsylvania; 2Philadelphia College of Osteopathic Medicine, Philadelphia, Pennsylvania; 3Combined Military Hospital, Lahore Medical College, Lahore, Pakistan
Sheharyar Minhas, MD1, Kevin Barretto...
Iatrogenic AV fistulas result from penetration of a needle through an arterial and venous tributary during angiographic catheterization procedures. Rarely, when the communication between the artery and vein does not seal spontaneously, an AV...
Iatrogenic AV fistulas result from penetration of a needle through an arterial and venous tributary during angiographic catheterization procedures. Rarely, when the communication between the artery and vein does not seal spontaneously, an AV...