Vascular closure devices

12/07/2015
The Vascade Vascular Closure System appears to be a useful addition to the collection of vascular closure devices, particularly in patients who are expected to undergo repeated coronary angiograms such as cardiac transplant recipients. Its...
The Vascade Vascular Closure System appears to be a useful addition to the collection of vascular closure devices, particularly in patients who are expected to undergo repeated coronary angiograms such as cardiac transplant recipients. Its...
The Vascade Vascular Closure...
12/07/2015
Cath Lab Digest
Clinical Editor's Corner
11/05/2014
Given what we now understand about closure devices and femoral angiography, I found it strange that this question would come up, but I put it out to my colleagues on the “Cath List” to see what the conversation might be. 
Given what we now understand about closure devices and femoral angiography, I found it strange that this question would come up, but I put it out to my colleagues on the “Cath List” to see what the conversation might be. 
Given what we now understand...
11/05/2014
Cath Lab Digest
New Devices
06/04/2014
The Mynx Ace (Figure 1A-B) uses the Grip Technology sealant, which is composed of two different components of polyethylene glycol. The tip is unreacted and not cross-linked. Upon deployment, human body temperature and pH level cause this...
The Mynx Ace (Figure 1A-B) uses the Grip Technology sealant, which is composed of two different components of polyethylene glycol. The tip is unreacted and not cross-linked. Upon deployment, human body temperature and pH level cause this...
The Mynx Ace (Figure 1A-B) uses...
06/04/2014
Cath Lab Digest
Tips and Techniques
05/21/2014
Surgical left atrial appendage (LAA) exclusion has a failure rate as high as 60% due to persistent residual flow in the LAA or large LAA remnants. We describe a novel technique for treatment of incomplete surgical LAA ligation, and define the...
Surgical left atrial appendage (LAA) exclusion has a failure rate as high as 60% due to persistent residual flow in the LAA or large LAA remnants. We describe a novel technique for treatment of incomplete surgical LAA ligation, and define the...
Surgical left atrial appendage...
05/21/2014
Journal of Invasive Cardiology
04/30/2014
Use of the Axera does not mean you are abandoning the traditional femoral access approach; this device is an attempt at modifying and hopefully improving it.
Use of the Axera does not mean you are abandoning the traditional femoral access approach; this device is an attempt at modifying and hopefully improving it.
Use of the Axera does not mean...
04/30/2014
Cath Lab Digest
Original Contribution
09/27/2013
This study found that venous access-site closure with a single 6 Fr suture-mediated Proglide during MitraClip procedures was feasible, safe, and effective.
This study found that venous access-site closure with a single 6 Fr suture-mediated Proglide during MitraClip procedures was feasible, safe, and effective.
This study found that venous...
09/27/2013
Journal of Invasive Cardiology
Tips and Techniques
08/29/2013
Arterial closure devices are commonly used to close the arteriotomy site in the common femoral artery (CFA) following angiographic coronary or peripheral vascular procedures; one potential complication is acute closure of the CFA by...
Arterial closure devices are commonly used to close the arteriotomy site in the common femoral artery (CFA) following angiographic coronary or peripheral vascular procedures; one potential complication is acute closure of the CFA by...
Arterial closure devices are...
08/29/2013
Journal of Invasive Cardiology
Tips and Techniques
07/30/2013
Off-label “double wire” technique for closure of large-bore vascular access has been reported in the setting of percutaneous aortic valvuloplasty. This paper presents 5 cases of high-risk PCI supported by a 2.5 LP Impella assist device with...
Off-label “double wire” technique for closure of large-bore vascular access has been reported in the setting of percutaneous aortic valvuloplasty. This paper presents 5 cases of high-risk PCI supported by a 2.5 LP Impella assist device with...
Off-label “double wire”...
07/30/2013
Journal of Invasive Cardiology
07/29/2013
The complication rate with the Mynx vascular closure device is low but there have been reports of distal embolization of the sealant. Optimal treatment of this complication is unknown with limited published data relating only to surgical...
The complication rate with the Mynx vascular closure device is low but there have been reports of distal embolization of the sealant. Optimal treatment of this complication is unknown with limited published data relating only to surgical...
The complication rate with the...
07/29/2013
Journal of Invasive Cardiology