Skip to main content

ADVERTISEMENT

percutaneous coronary intervention

Commentary
06/27/2017
For radial access to become the dominant access route, United States interventionalists will need embody the “perfect example of the practitioner of his or her craft,” or “compleat” radialists.
For radial access to become the dominant access route, United States interventionalists will need embody the “perfect example of the practitioner of his or her craft,” or “compleat” radialists.
For radial access to become the...
06/27/2017
Journal of Invasive Cardiology
Original Contribution
06/27/2017
This prospective study assesses balloon-assisted tracking in reducing radial access failure during percutaneous coronary intervention.
This prospective study assesses balloon-assisted tracking in reducing radial access failure during percutaneous coronary intervention.
This prospective study assesses...
06/27/2017
Journal of Invasive Cardiology
Clinical Images
04/25/2017
A 62-year-old man was referred for percutaneous coronary intervention of a severe circumflex lesion. The guidewire became entangled in the previously implanted left anterior descending artery stent. Caution should be used when wiring through...
A 62-year-old man was referred for percutaneous coronary intervention of a severe circumflex lesion. The guidewire became entangled in the previously implanted left anterior descending artery stent. Caution should be used when wiring through...
A 62-year-old man was referred...
04/25/2017
Journal of Invasive Cardiology
Original Contribution
04/15/2017
We sought to describe trends in the use of preprocedural P2Y12 inhibitors and their clinical impact in patients undergoing percutaneous coronary intervention (PCI).
We sought to describe trends in the use of preprocedural P2Y12 inhibitors and their clinical impact in patients undergoing percutaneous coronary intervention (PCI).
We sought to describe trends in...
04/15/2017
Journal of Invasive Cardiology
Original Contribution
04/15/2017
Fractional flow reserve (FFR) value between 0.75 and 0.80 is considered the "gray zone" and outcomes data relative to treatment strategy (revascularization vs medical therapy alone [deferral]) are limited for this group. A total of 238...
Fractional flow reserve (FFR) value between 0.75 and 0.80 is considered the "gray zone" and outcomes data relative to treatment strategy (revascularization vs medical therapy alone [deferral]) are limited for this group. A total of 238...
Fractional flow reserve (FFR)...
04/15/2017
Journal of Invasive Cardiology
Original Contribution
02/28/2017
We assessed the feasibility and safety of the “single-operator” technique in which the operator autonomously advanced the orbital atherectomy device while maintaining wire position.
We assessed the feasibility and safety of the “single-operator” technique in which the operator autonomously advanced the orbital atherectomy device while maintaining wire position.
We assessed the feasibility and...
02/28/2017
Journal of Invasive Cardiology
01/31/2017
The SoundBite Crossing System (SoundBite Medical Solutions, Inc) is a newly-developed device using shockwaves (short-duration, high-amplitude pressure pulses) delivered to the tip of guidewire to facilitate penetration of the proximal cap and...
The SoundBite Crossing System (SoundBite Medical Solutions, Inc) is a newly-developed device using shockwaves (short-duration, high-amplitude pressure pulses) delivered to the tip of guidewire to facilitate penetration of the proximal cap and...
The SoundBite Crossing System...
01/31/2017
Journal of Invasive Cardiology
Original Contribution
01/31/2017
We analyzed the incidence of bradycardia and the safety of patients with severely calcified coronary lesions who underwent orbital atherectomy without the insertion of a temporary pacemaker.
We analyzed the incidence of bradycardia and the safety of patients with severely calcified coronary lesions who underwent orbital atherectomy without the insertion of a temporary pacemaker.
We analyzed the incidence of...
01/31/2017
Journal of Invasive Cardiology