Skip to main content

ADVERTISEMENT

Transcatheter heart valve

Clinical Images
06/12/2024

Rawan Mahmoud, MD1; Mohammad Alkhalil, MD1,2

Rawan Mahmoud, MD1; Mohammad Alkhalil...
The authors describe the use of parallel wires to aid the implantation of a transcatheter heart valve in a patient who lacked significant aortic valve calcification.
The authors describe the use of parallel wires to aid the implantation of a transcatheter heart valve in a patient who lacked significant aortic valve calcification.
The authors describe the use of...
06/12/2024
Journal of Invasive Cardiology
Basman Figure
Clinical Videos
03/13/2024

Craig Basman, MD; Sung-Han Yoon, MD; Vladimir Jelnin, MD; Ryan Kaple, MD

Craig Basman, MD; Sung-Han Yoon, MD; ...
Video Supplement to "Snare Technique to Facilitate ‘Tall-in-Short’ Redo-TAVR" (Clinical Image).
Video Supplement to "Snare Technique to Facilitate ‘Tall-in-Short’ Redo-TAVR" (Clinical Image).
Video Supplement to "Snare...
03/13/2024
Journal of Invasive Cardiology
Clinical Images
03/13/2024

Craig Basman, MD; Sung-Han Yoon, MD; Vladimir Jelnin, MD; Ryan Kaple, MD

Craig Basman, MD; Sung-Han Yoon, MD; ...
An 82-year-old man with a prior history of transcatheter aortic valve replacement with a 23-mm balloon-expandable transcatheter heart valve presented with bioprosthetic stenosis.
An 82-year-old man with a prior history of transcatheter aortic valve replacement with a 23-mm balloon-expandable transcatheter heart valve presented with bioprosthetic stenosis.
An 82-year-old man with a prior...
03/13/2024
Journal of Invasive Cardiology
Original Contribution
03/13/2024

Alberto Alperi, MD, PhD1,2; Cesar Moris, MD, PhD1,2,3; Raquel del Valle, MD1; Isaac Pascual, MD, PhD1,2,3; Paula Antuna, MD1; Marcel Almendárez, MD, PhD1; Daniel Hernández-Vaquero, MD, PhD1,2; Jose Luis Betanzos, MD1; Josep Rodés-Cabau, MD, PhD4; Pablo Avanzas, MD, PhD1,2,3,5

Alberto Alperi, MD, PhD1,2; Cesar Mor...
The authors aimed to evaluate the hemodynamic performance of 2 self-expandable systems (Evolut and Acurate Neo) during several timepoints of valve implantation in a real-life scenario.
The authors aimed to evaluate the hemodynamic performance of 2 self-expandable systems (Evolut and Acurate Neo) during several timepoints of valve implantation in a real-life scenario.
The authors aimed to evaluate...
03/13/2024
Journal of Invasive Cardiology
Clinical Images
09/01/2022

Gianpiero D’Amico, MD, PhD;  Francesco Gallo, MD;  Giovanni Vescovo, MD;  Federico Ronco, MD;  Marco Barbierato, MD

Gianpiero D’Amico, MD, PhD;  Francesc...
A 91-year-old man presented with syncope secondary to severe aortic stenosis. A transthoracic echocardiogram revealed a calcified stenotic trileaflet aortic valve with a mean gradient of 60 mmHg.
A 91-year-old man presented with syncope secondary to severe aortic stenosis. A transthoracic echocardiogram revealed a calcified stenotic trileaflet aortic valve with a mean gradient of 60 mmHg.
A 91-year-old man presented with...
09/01/2022
Journal of Invasive Cardiology
Original Contribution
01/31/2017

Uri Landes, MD;  Tamir Bental, MD;  Alon Barsheshet, MD;  Abid Assali, MD;  Hana Vaknin Assa, MD;  Amos Levi, MD;  Katia Orvin, MD;  Ran Kornowski, MD

Uri Landes, MD;  Tamir Bental, MD;  A...
We compared transcatheter aortic valve implantation outcomes of the Evolut-R and CoreValve devices. This study indicates that the efficacy and safety of the self-expandable second-generation Evolut-R transcatheter valve is at least comparable...
We compared transcatheter aortic valve implantation outcomes of the Evolut-R and CoreValve devices. This study indicates that the efficacy and safety of the self-expandable second-generation Evolut-R transcatheter valve is at least comparable...
We compared transcatheter aortic...
01/31/2017
Journal of Invasive Cardiology